Klimaire KSIO018-H221 Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Nein Klimaire KSIO018-H221 herunter. Klimaire KSIO018-H221 Installation Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 2
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
1. Determine hole positions according to left and right
side of the installation plate. The hole center is obtained
by measuring the distance as shown in the diagram above.
2. Dirll the piping plate hole with φ65mm hole-core drill.
3. Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
4. Always take steps to protect the pipe when drilling metal
grid,metal plate or the like.
INSTALLATION MANUAL FOR
KSIO ROOM AIR CONDITIONER
(Split Wall-Mounted Type)
DRILL A HOLE IN THE WALL
INSTALLATION PLATE MOUNTING
2
1
I
N
D
O
O
R
U
N
I
T
Please read these safety precautions carefully before installation
Be sure to follow all the precautions below, they are all important for ensuring safety.
This symbol indicates the possibility of death or serious injury.
This symbol indicates the possibility of injury or damage to property.
1) This equipment must be grounded and installed with ground leakage current breaker. It may cause
electricalshockifgroundingisnotperfect.
2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and
accumulates at surrounding of the unit, it may cause fire.
3) Carry out drainage piping as mentioned in installation instructions. If drainage is not perfect, water
may enter the room and damage the furniture.
1) Install according to this installation instructions strictly. If installation is defective, it will cause water
leakage,electricalshock,orfire.
2) Use the included accessories parts and specified parts for installation. otherwise, it will cause the set
tofall,water leakage,electricalshock, orfire.
3) Install at a strong and firm location which is able to withstand the set s weight. If the strength is not
enoughorinstallationisnotproperlydone,thesetwilldropandcauseinjury.
4) For electrical work, follow the local national wiring standard, regulation and this installation instructions.
Anindependentcircuitandsingleoutletmustbeused.Ifelectricalcircuitcapacityisnotenoughor
defectfoundinelectricalwork,itwillcauseelectricalshock, or fire.
5) Use the specified cable and connect tightly and clamp the cable so that no external force will be acted
ontheterminal.Ifconnectionorfixingisnotperfect,itwillcauseheat-uporfireattheconnection.
6) Wiring routing must be properly arranged so that control board cover is fixed properly. If control board
coverisnotfixedperfectly, it will overheatatconnectionpointofterminal,fireorelectricalshock.
7) When carrying out piping connection, take care not to let air substances other than the specified
refrigerantgointorefrigerationcycle.Otherwise,itwillcauselowercapacity,abnormalhighpressure
intherefrigerationcycle,explosionandinjury.
8) Do not modify the length of the power supply cord or use of extension cord, and do not share the
singleoutletwithotherelectricalappliances.Otherwise,itwillcausefireorelectricalshock.
SAFETY PRECAUTIONS
CAUTION
WARNING
CAUTION
WARNING
Please read this installation manual carefully before operating the unit to ensure correct installation.
If the power cord is damaged, replacement work shall be performed by authorised personnel only.
Installation must be performed in accordance with the requirement of NEC and CEC by authorized
personnel only.
Contact an authorized service technician for repair, maintenance and installation of this unit.
This appliance is not intended for use by persons(including children) with reduced physical, sensory
or mental capabilities, or lack of experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by persons responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
All the pictures in the instructions are for explanation purposes only. The actual shape should prevail.
The design and specifications are subject to change without prior notice for product improvement.
Consult with the sales agency or manufacturer for details.
There should not be any heat source or stream
near the unit.
There should not be any obstacles blocking the
air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into
consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the
wall,ceiling,fence or other obstacles.
There should not be any direct sunlight. If unavoidable,
sunlight prevention should be taken into consideration.
Ou
t
d
o
or
u
n
i
t d
ime
n
s
i
o
n
m
m
(WxH
x
D
)
A(mm) B(mm)
530
290
560
335
481
549
276
276
Mounting dimensions
670x540x265
780x540x250
760x590x285
845x700x320
Indoor unit
Outdoor unit
If an awning is built over the unit to prevent
direct sunsight or rain,be careful that heat
radiation from the condenser is not obstructed.
There should not be any animal or plant which
could be affected by hot air discharged.
Keep the spaces indicated by arrow from wall
ceiling, fence or other obstacles.
Do not place any obstacles which may cause
a short circuit of the discharged air.
Anchor the outdoor unit with a bolt and nut φ10 or
φ8 tightly and horizontally on a concrete or rigid mount.
Settlement of outdoor unit
NOTE: The outdoor unit you purchase may be like one
of the following. Install the outdoor unit according to the
dimension as indicated in the table below:
A
W
B
D
Air inlet
Air outlet
Air inlet
INSTALLATION PRECAUTIONS
CONNECT THE CABLE TO THE INDOOR UNIT
3
,
Terminal block of indoor unit
Connect the cable to the indoor unit
Before performing any electrical work, turn off the main power to the system.
1. The inside and outside connecting cable can be connected without removing the front grille.
2. The indoor power cord type is H05VV-F or H05V2V2-F, the outdoor power cord and
interconnected cord type is H07RN-F.
3. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw.
4. Ensure the colour of wires of outdoor unit and the terminal Nos. are the same to the indoor s
respectively.
5. Wrap those cables not connected with terminals with insulation tapes, so that they will not touch
any electrical components. Secure the cable onto the control board with the cord clamp.
NOTE:
Electronic box
cover
Front Panel
To outdoor unit
To outdoor unit
or
S
S
N
N
L
L
1
2
3
4
5
7
8
9
10
6
Installation Plate
Clip Anchor
Self-tapping Screw A ST3.9x25
Seal(For cooling & heating models only)
Drain Joint(For cooling & heating models only
Connecting
pipe
Assembly
Liquid side
Gas side
Remote controller
Self-tapping Screw B ST2.9x10
Φ6.35
Φ9.52
Φ9.52
Φ12.7
Φ 16
Parts you must purchase. The pipe
size differ from appliance to appliance.
Consult the technician for the proper
size.
1
5-8(depending on models)
5-8(depending on models)
1
1
1
2
1
1
Except the above parts provided,the other parts needed during installation you must
purchase.
Remote controller holder
ACCESSORIES
Number
Name of Accessories
Qty
NOTE:
optional
parts
SELECT THE BEST LOCATION
4
CONNECTIVE PIPE AND DRAINAGE INSTALLATION
1. Run the drain hose sloping downward.
Do not install the drain hose as illustrated
in wrong figures.
2. When connecting extension drain hose,
insulate the connecting part of extension
drain hose with a shield pipe, do not let
the drain hose slack.
Drainage
Right
Wrong
Correct orientation
of Installation Plate
1. Fit the installation plate horizontally on
structural parts of the wall withspaces
around the installation plate.
2. If the wall is made of brick, concrete
or the like, drill five or eight 5mm
diameter holes in the wall. Insert
clip anchor for appropriate mounting
screws.
3. Fit the installation plate on the wall
with five or eight type A screws.
Mount the Installation Plate and drill
holes in the wall according to the wall
structure and corresponding mounting
points on the installation plate. The
installation plate providedwith the
machine differ from appliance
to appliance.(Dimensions are in
mm unless otherwise stated)
NOTE:
NOTE:
"
"
Installation Plate Mounting
The mounting wall is strong and solid enough
to prevent it from the vibration.
45
45
280
120mm or
more to wall
120mm or
more to wall
120mm or
more to wall
150mm or more to ceiling
150mm or more to ceiling
Left rear side
refrigerant
pipe hole φ65
36.5
835
140
110
Left rear side
refrigerant
pipe hole φ65
Right rear side
refrigerant
pipe hole φ65
Right rear side
refrigerant
pipe hole φ65
Indoor unit outline
Indoor unit outline
120mm or
more to wall
120mm or
more to wall
Indoor unit outline
990
315
135
260
150mm or more to ceiling
Left rear side
refrigerant
pipe hole φ65
Right rear side
refrigerant pipe
hole φ65
Model C
Model D
Model B
Model A
120mm or
more to wall
45
45
36.5
750
180
110
280
Right rear side
refrigerant pipe
hole φ65
Left rear side
refrigerant
pipe hole φ65
150mm or more to ceiling
Installation plate
Indoor unit outline
120mm or
more to wall
120mm or
more to wall
1186
21.5
275
275
343
45
549
590
325
333
810x558x310
900x860x315
Suggest Minimum Wire Size (AWG:American Wire Gage):
Appliance Amps
AW G Wire S ize
10
13
18
25
18
16
14
12
30
40
10
8
Air freshening filter(used to install on Air filter)
Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to install
the air conditioner and explain to the client until the problem is solved.
2. Power voltage should be in the range of 90%~110%of rated voltage.
3. The surge protector and main power switch with a 1.5 times capacity of Max. Current of the unit should
be installed in power circuit. Ensure the air conditioner is grounded well.
4. The appliance shall be installed in accordance with national wiring regulations. Do not operate your air
conditioner in a wet room such as a bathroom or laundry room.
5. An all-pole disconnection device which has at least 3mm clearances in all poles, and have a leakage
current that may exceed 10mA, the residual current device(RCD) having a rated residual operating
current not exceeding 30mA, and disconnection must be incorporated in the fixed wiring in accordance
with the wiring rules.
6. For the unit adopts auxiliary electric heater, keep at least 1 meter away from the nearest combustible
materials.
7. According to the attached Electrical Connection Diagram located on the panel of the indoor & outdoor
unit to connect the wire.
8. All wiring must comply with local and national electrical codes and be installed by qualified and
skilled electricians.
9. An individual branch circuit and single receptacle used only for this air conditioner must be
available. See the following table for suggested wire sizes and fuse specifications:
Electrical work
The wire size of power supply cord and
interconnected wire and the current of the fuse or
switch are determined by the maximum current
indicated on the nameplate which located on the
side panel of the unit. Please refer to the nameplate
before selecting the wire size, fuse or switch.
The controller of the air conditioner designed with
a fuse protection function under abnormal
conditions, the specifications of the fuse have
printed on the circuit board, such as:
T3.15A/250VAC, T5A/250VAC, etc.
NOTE:
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1 - DRILL A HOLE IN THE WALL

1. Determine hole positions according to left and right side of the installation plate. The hole center is obtained by measuring the distance

Seite 2 - REFRIGERANT PIPE CONNECTION

Tel: (305)593-8358 Fax (305) 675-2212www.klimaire.com [email protected] NW 89 Place, Doral, FL 33172 - USAThe Klimaire logo is a registered

Kommentare zu diesen Handbüchern

Keine Kommentare